unattended.xml and the secret of Language

There are some articles on my blog about the Language settings in unattended File. in this Post I will talking about the hole understanding, I hope you can follow me if you open the ImageX-tool that is installed on your WAIK infrastructure you can easily create an unattend.xml file with click and dirty. But there [...]

Posted on July 14, 2011 at 10:43 by mirko colemberg · Permalink · 2 Comments
In: OSD, sccm, Tasksequence, Win 7 Design · Tagged with: , ,

Citrix XenServer SCCM PXE-boot loops

have you the problem that your PXE-boot looks good for the first boot, but is the Task sequence going to prepare the first reboot, after this the WinPE Boot Loops So the problem is that Citrix has a special PXE-Agent. Go to your XenServer environment and in the Properties of Boot order change that the [...]

Posted on June 16, 2011 at 16:23 by mirko colemberg · Permalink · Leave a comment
In: pxe, sccm, Tasksequence · Tagged with: , , ,

OSD Capturing an OS Image Error

If you have any Problems with the Messages: “The specified network password is not correct.  (Error: 80070056; Source: Windows)” and ”The network path was not found. (Error: 80070035; Source: Windows) Unloading offline SYSTEM registry hive” There is a Problem with the WinPE Image or check first your Boundaries in SCCM enviroment. Solution: Create a new [...]

Posted on March 9, 2011 at 11:42 by mirko colemberg · Permalink · Leave a comment
In: OSD, sccm, Tasksequence · Tagged with: ,

Program exit code 259

in the Execmgr.log you have a line that means “Program exit code 259” i have never heard from this Program Exit Code in SCCM! On the Technet you can find this Forum-Post: Technet Post In Short: This Code are from the Vendor not from the ConfigMgr, so in Tasksequence you can give this Code in [...]

Posted on October 12, 2010 at 13:48 by mirko colemberg · Permalink · Leave a comment
In: client, Errors, sccm, Tasksequence · Tagged with: , ,

Setup Windows and ConfigMgr – 0×80004005

The following error: “Task Sequence: xxxxx has failed with the error code (0×80004005). For more information, please contact your system administrator or helpdesk operator.” on Setup Windows and ConfigMgr step check the Product Key! Maybe the Product key from youre Windows Version is not correct, so either write another one or remove the product key at ”Apply Windows Settings” [...]

Posted on September 18, 2010 at 12:49 by mirko colemberg · Permalink · Leave a comment
In: Errors, sccm, Tasksequence · Tagged with: , ,

Failed to call SMS_TaskSequence::LoadFromXml due to error 8004100a

In the Console you have Problem to open a Tasksequenze, failure is Can not load the Tasksequence Reboot youre Server, is magic but it works have fun, no guarante

Posted on August 31, 2010 at 14:52 by mirko colemberg · Permalink · Leave a comment
In: Errors, sccm · Tagged with: , ,

TaskSequnce failure Code(0×80040104)

Have you this Code(0×80040104) in smsts.log on youre client that would you to deploy, so enable F8 function in the WinPE and show the end of log. Failed to find CCM_SoftwareDistribution object for AdvertID=”HOI20203″, PackageID=”HOI00652″,Failed to find … ….. Failed to resolve selected task sequence dependencies. Code(0×80040104)        TSPxe    8/13/2010 1:55:07 PM    1308 (0x051C)…… is it two [...]

Posted on August 13, 2010 at 10:23 by mirko colemberg · Permalink · Leave a comment
In: client, Errors, sccm, Tasksequence · Tagged with: , , ,

Rename Local Administrator Account W7

In Win 7  you have a lot of options, so you can rename the local-Admin Account to make it difficult for root-kidis. Or you want to be secure in youre enviroment so you can use this examples; http://www.sevenforums.com/tutorials/7417-built-administrator-account-change-name.html or create a inf-File and use it with comandline RenSdtADM.inf: [Unicode] Unicode=yes [Version] signature=”$CHICAGO$” Revision=1 [System Access] [...]

Posted on August 3, 2010 at 12:28 by mirko colemberg · Permalink · Leave a comment
In: sccm, scripts, Tasksequence, Win 7 Design · Tagged with: , , ,

USMT 4.0 migration from XP to Win7

Somtimes you have a Migration scenario that’s not best practies, so you have constellations for migrations that verry customized. In this Post is only spoken from SCCM SP2 R2 Tasksequence! Here You have a Blog from Peter van der Woude, thanx for him to Post verry helpfull stuff and also greatfull Blog over Windows-Noob from [...]

Posted on July 2, 2010 at 09:30 by mirko colemberg · Permalink · Leave a comment
In: client, sccm, Tasksequence · Tagged with: , , , ,

TaskSequence Variables

Here you can show the Standard Variables in a Task Sequence is it from MS Technet

Posted on July 1, 2010 at 07:43 by mirko colemberg · Permalink · Leave a comment
In: client, Tasksequence · Tagged with: ,